Minneapolis BlowerDoor The market-leading airtightness measuring system
From clean rooms to high-rise buildings: With two fan sizes and the ability to combine multiple systems, the Minneapolis BlowerDoor is predestined for measuring airtightness in all building types and sizes.
The measurement systems are characterized by outstanding accuracy and durability. The BlowerDoor test for quality assurance is software-based, as is the measurement according to ISO 9972. Optionally, a semi-automatic or manual BlowerDoor measurement can be performed.
With specific add-on components, Minneapolis BlowerDoor measuring systems are also successfully used to solve other tasks.
Proven add-ons are, for example, the determination of extinguishing gas holding times with the BlowerDoor FireProtection software, the leakage testing of ventilation ducts and the component testing with the Minneapolis Micro Leakage Meter, Bau.Tools BlowerDoor for the all-season sequential analysis by means of BlowerDoor and thermography as well as testing the air permeability of windows with the Window and Door Measurement System.
Benefit from our large range of goods, e. g. BlowerDoor mounting frames, panels with one or more openings, BlowerDoor fans, pressure gauges, transport bags, accessories and spare parts.
With the new TECTITE Express 5.1 software you can conduct highly accurate automated, semi-automated and manual BlowerDoor tests in accordance with ISO 9972 and EN 13829. The TECLOG Software is ideal for the use in large buildings as well as for the measurment with the Micro Leakage Meter, the FlowBlaster, and the Window and Door Measuring System.
In addition to the very high quality factory calibration, BlowerDoor GmbH also offers calibrations with DAkkS certificate for the pressure gauges and BlowerDoor measuring fans on accredited test benches. The extensive investments in accreditations were made in order to meet the increasing requirements of national and international standards. Part of our calibrations is an extensive functional test as well as the adjustment of the pressure measuring devices.
(Note: Laboratory accredited by DAkkS according to DIN EN ISO/IEC 17025:2018. The accreditation is only valid for the scope of accreditation listed in the annex to the certificate D-K-19788-01-00.)
Do you intend to enlarge your BlowerDoor system for a one-time use? Benefit from our rental service at favorable conditions for your temporary needs. Please note: The rental prices quoted are for one BlowerDoor measurement within 7 days. A prolongation for a surcharge is possible and need an agreement, please contact us!
Calibration by accredited laboratory (EN 17025) for flow rings of BlowerDoor MiniFan (model DuctBlaster).
Three measured values are calibrated per flow ring. The measuring accuracy of the BlowerDoor fan of ± 4 % (open fan and rings 1-4) is assessed (DAkkS certificate).
Previous basic maintenance and functional test included. Monthly calibration dates. Your binding registration is required.
Calibration by accredited laboratory (EN 17025) for flow rings of BlowerDoor Standard (model 4, model 3).
Three measured values are calibrated per flow ring. The measuring accuracy of the BlowerDoor fan of ± 4 % (open fan and rings A – C) and ± 5 % (rings D and E) is assessed (DAkkS certificate).Previous basic maintenance and functional test included. Monthly calibration dates. Your binding registration is required.
The functional test of the BlowerDoor measuring fans includes: - Visual inspection for damage such as breaks or cracks - Inspection of tube connections to the E-box - Inspection of rivets, bolts, impeller, flow sensor, wiring harness, orifice clips, motor mount - and motor running - Measurement of the motor distance - Blowing out the motor housing with compressed air to remove dust
Calibration according to manufacturer's specification for flow rings of BlowerDoor MiniFan (model DuctBlaster).
One measured value is calibrated per flow ring. The requirement of ISO 9972 (measuring accuracy of the measuring system ± 7 %) is assessed (calibration certificate).Previous basic maintenance and functional test included. Recommended calibration interval 4 years.Flexible calibration dates according to customer requirements. Registration desired to ensure short calibration times of max. 5 working days.
Calibration according to manufacturer's specification for flow rings of BlowerDoor Standard (model 4). One measured value is calibrated per flow ring. The requirement of ISO 9972 (measuring accuracy of the measuring system ± 7 %) is assessed (calibration certificate). Previous basic maintenance and functional test included. Recommended calibration interval 4 years. Flexible calibration dates according to customer requirements. Registration desired to ensure short calibration times of max. 5 working days.
Special offer in the context of calibration!
Essential for fans BlowerDoor Standard model 3 and model 4 until 09/2006. Set of flow rings incl. ring clips, fan cap and retrofitting.
with interior lining suitable for the measuring fan BlowerDoor Standard. Special prices in the context of fan calibration:
- buying 70.00 EUR - renting (return after calibration) 20.00 EUR
€70.00*